BETA

Thermal Conductivity

Thermal conductivity of early-age concrete: from the mix and the aggregate type, or fitted to conductivity measured at its curing temperatures.

Thermal conductivity of hardened concrete

The thermal conductivity of hardened concrete, ku, is computed from the conductivities and volume fractions of the coarse aggregate, fine aggregate, paste and air, obtained from the mixture proportions, using a selectable homogenization rule. The aggregate governs the result; its mineralogy has a considerably greater influence than the composition of the binder.

The rules are written for the volume fractions Vi and conductivities ki of the four phases (i = paste, fine aggregate, coarse aggregate, air), with k = 0.026 W/m·K for air:

Geometric mean
ku = ∏i kiVi
Parallel (upper bound)
ku = ∑i Vi ki
Series (lower bound)
1 / ku = ∑i Vi / ki

The Hashin–Shtrikman mean is the average of the two bounds of a matrix m containing inclusions p:

Lower and upper bounds
k1 = km + Vp / [ 1 / (kp − km) + Vm / (3km) ]
k2 = kp + Vm / [ 1 / (km − kp) + Vp / (3kp) ]
Hashin–Shtrikman mean
kHS = (k1 + k2) / 2

It is applied in two steps. The paste is the matrix and the aggregate the inclusion, with the fraction Va / (Vpaste + Va). The result is then the matrix for the air voids, at the air fraction. The fine and coarse aggregate are first combined into one aggregate phase:

Aggregate phase
ka = exp[ (Vf ln kf + Vc ln kc) / Va ],   Va = Vf + Vc

The conductivity of fresh concrete exceeds that of hardened concrete by approximately one third and decreases as hydration proceeds. In the thermal analysis this dependence is represented by the following relation, independent of binder type, so that only ku is required here, either computed or measured:

Conductivity with hydration
k(α) = ku (1.33 − 0.33α)

The specific heat is evaluated within the thermal analysis from the mixture proportions and the degree of hydration, where W is the mass per unit volume of the binder (b), water (w), and fine (f) and coarse (c) aggregate, cb is the mass-weighted specific heat of the binder, and T is the concrete temperature in °C:

Specific heat
cp(α) = [ Wbα(8.4T + 339) + Wb(1 − α)cb + 710Wf + 840Wc + 4184Ww ] / ρ

Calibration to test data. ku is fitted by least squares to conductivity kj measured at several ages tj and curing temperatures Tj (in K):

Equivalent age
te = t exp[ −(Ea / R)(1 / T − 1 / Tref) ]
Degree of hydration
α(te) = αu exp[ −(τ / te)β ]
Least-squares fit
ku = ∑j kjgj / ∑j gj2,   gj = 1.33 − 0.33αj

References. Hashin & Shtrikman (1962). A variational approach to the theory of the effective magnetic permeability of multiphase materials. Journal of Applied Physics, 33, 3125–3131. Mardmomen & Chen (2023). Modeling the thermal and mechanical properties of early age concrete containing ground granulated blast furnace slag. Construction and Building Materials, 401, 132902.