BETA

On-site Insulated Cube

Measure the heat of hydration of the concrete delivered to site with an insulated cube.

Semi-adiabatic calorimetry with an insulated cube

A concrete cube, enclosed in insulated foam boards, is cast from the concrete delivered to the project. The temperature at the centre of the cube approaches adiabatic conditions; the small heat loss through the insulation is quantified from the measured surface temperatures and added back, yielding the adiabatic temperature rise of the concrete as placed.

From this temperature rise and the mixture proportions, the heat of hydration is derived and the degree-of-hydration parameters (αu, τ, β) are determined for use in the thermal analysis. The ultimate heat and the ultimate degree of hydration account for the phase composition of the cement and for slag or fly ash in the binder.

Assembled insulated cube form of foam boards in a timber frame, with plan and elevation drawings giving the plywood and foam board dimensions
Insulated cube setup: the assembled form, with plan and elevation dimensions. From Chen, Mardmomen & Leon (2021).

References. Chen, Mardmomen & Leon (2021). On-site measurement of heat of hydration of delivered mass concrete. Construction and Building Materials, 269, 121246.